Brand Name : Kacise
Model Number : KBU601
Certification : certificate of explosion-proof, CE
Place of Origin : China (Mainland)
MOQ : 0-100
Payment Terms : Western Union, MoneyGram, T/T
Supply Ability : 100
Delivery Time : 5-8 working days
Packaging Details : each unit has individual box and all boxes are packed in standard packages or customers requests available
Measuring range : 0~2.000mg/L(HClO)
Accurate : ±5% or ±0.05mg/L
Output : RS485
Resolution : 0.001mg/L
Installation : Circulation pool installation
Protection level : IP68
1. Applications
Kacise on-line residual chlorine sensor is used to monitor the residual chlorine content continuously in drinking water treatment plant, canning plant, drinking water distribution network, swimming pool, cooling circulating water, water quality treatment project.
2. Feature
3. Technical Specifications
| Module No. | KWS-3000 | 
| Principle | the constant voltage method | 
| Range | 0~2.000mg/L(HClO) | 
| Accurate | ±5% or ±0.05mg/L | 
| Resolution | 0.001mg/L | 
| Calibration Function | Two point Calibration (Zero and Slope ) | 
| Temperature Compensation | Temperature compensation automatically (Digit temperature sensor) | 
| Working temperature | 0 ~ 50℃ | 
| Output | Support RS-485, MODBUS protocol | 
| Power Supply | 12~24VDC±10% | 
| Velocity | 30-60 L/h | 
| Installation | Circulation pool installation | 
| size | 30×233mm(Φ×L) | 
| Protection | IP68 | 
| Material | Polyacetal resin, PTFE, Gold, Silver Polyformaldehyde resin, teflon, gold, silver, electro conductive rubber | 
4. Outline

5. Electric Connect
The electrode should be installed closely with the circulation pool. The electrode measurement part should be placed in the area near the circulation pool inlet. It is not allowed to face the outlet. Ensure the smooth flow . We suggest to control the flow rate within 30-60l /h to ensure the test accuracy.
Red: Power supply (12~24V)
Black: Ground(GND)
Blue: 485A
White: 485B
Exposed wire: shielded wire
Please make sure that you connect the wire correctly.
Cable specifications: the cable has a certain corrosion resistance, considering that it has been immersed in water (including seawater) or exposed to air for a long time. The diameter is Φ6 mm. Please make the waterproof processing on cable joint.
5. Maintenance
1) Sensor detection and maintenance
The new electrode and the electrode placed for a long time should be activated before use. The sensor shall be left in the tap water for 24 hours.If the returned value is not correct, please make the following operation.
2) Calibration of sensors
a) zero point calibration: the sensor probe is placed in chlorine-free water for zero point calibration after the numerical stability.
B) slope calibration: the sensor probe is placed in the flow pool with residual chlorine standard liquid, and the slope calibration is performed after the value is stable. Suggest to use 1-2mg/L HCIO standard solution. About the preparation and determination of the standard liquid, we can refer to the determination of residual chlorine standard.
Note: the sensor has been calibrated before delivery. Since the preparation of its standard liquid has high requirements on personnel, non-professionals may not be qualified for this job. Only if the value is determined to be inaccurate, it is recommended that the user do not calibrate the sensor.


  
|   | 
| Digital Water Flow Sensor Circulation Pool Installation 30 - 60 L/H Velocity Images | 
 Intelligent Water Quality Sensor Fiber Optic Chlorophyll Sensor RS485 Transmissi
                                                                                    
                        
                        
                        
                                                            Intelligent Water Quality Sensor Fiber Optic Chlorophyll Sensor RS485 Transmissi
                                                    
                        
                     Aquaculture Fluorescence Dissolved Oxygen Sensor High Accuracy 22mm Casing
                                                                                    
                        
                        
                        
                                                            Aquaculture Fluorescence Dissolved Oxygen Sensor High Accuracy 22mm Casing
                                                    
                        
                     Accurate 10% Water Quality Sensor RS485 Output Multi Parameter
                                                                                    
                        
                        
                        
                                                            Accurate 10% Water Quality Sensor RS485 Output Multi Parameter
                                                    
                        
                     Environmentally Friendly COD Sensor / Kws-100 Cod Measurement Instrument
                                                                                    
                        
                        
                        
                                                            Environmentally Friendly COD Sensor / Kws-100 Cod Measurement Instrument
                                                    
                        
                     NH4-N Ammonia Nitrogen Water Quality Sensor KWS-200 PH Range 4-10
                                                                                    
                        
                        
                        
                                                            NH4-N Ammonia Nitrogen Water Quality Sensor KWS-200 PH Range 4-10
                                                    
                        
                     90° Scattered Light Aquaculture Industry Water Turbidity Sensor 0 - 1000NTU
                                                                                    
                        
                        
                        
                                                            90° Scattered Light Aquaculture Industry Water Turbidity Sensor 0 - 1000NTU
                                                    
                        
                     Radial Installation Manometer Pressure Gauge Pressure Monitoring Storage
                                                                                    
                        
                        
                        
                                                            Radial Installation Manometer Pressure Gauge Pressure Monitoring Storage
                                                    
                        
                     Electromagnetic flowmeter for measuring liquid flow 0.6-4.0MPa pressure with
                                                                                    
                        
                        
                        
                                                            Electromagnetic flowmeter for measuring liquid flow 0.6-4.0MPa pressure with
                                                    
                        
                     Support MODBUS and RS-485 output digital oil in water sensors support MODBUS and
                                                                                    
                        
                        
                        
                                                            Support MODBUS and RS-485 output digital oil in water sensors support MODBUS and
                                                    
                        
                     Dissolved Oxygen Sensor Water Quality Sensor IP68 Grade For Shrimp Farm
                                                                                    
                        
                        
                        
                                                            Dissolved Oxygen Sensor Water Quality Sensor IP68 Grade For Shrimp Farm