Brand Name : KACISE

Model Number : M18 KUS1000

Certification : CE

Place of Origin : CHINA

MOQ : 1PCS

Payment Terms : T/T,Western Union,MoneyGram

Supply Ability : 1000 Piece/Pieces per Week negotiable

Delivery Time : 5-8 work days

Packaging Details : each unit has individual box and all boxes are packed in standard packages or customers requests available

Product : Ultrasonic Distance Sensor

Detection Range : 50mm~1000mm

Transducer Frequency : 40KHZ

Operating Voltage : 24VDC

Limit Working Voltage : 3.6VDC~30VDC

IP grade : IP67

Output : RS232/RS485

Contact Now

RS485 Output Signal low cost price ultrasonic liquid level meter gauge ultrasonic tank water level sensor
RS485 Output Ultrasonic Liquid Level Sensor with 50mm~1000mm Detection Range and IP67 Protection
1. Parameter
General specifications
Sensing range 100... 1000 mm
Unusable area 0 ... 100 mm
Standard target plate 100 mm x 100 mm
Transducer frequency approx.220 kHz
Response delay approx. 50 ms
Indicators/operating means
LED blue power-on

LED yellow

indication of the switching state

flashing: program function object detected

LED red

permanently red: Error Red,flashing:program function,object not detected
Electrical specifications
Operating voltage UB 15 ... 30 V DC , ripple 10 %SS
No-load supply current I0 ≤ 45 mA
Input
Input type 1 TEACH-IN input

operating range A1: -UB ... +1 V, operating range A2: +6 V ...+UB

input impedance: > 4.7 kΩ ; TEACH-IN program pulse: ≥ 1 s
Output
Output type 1 switch output E4, NPN NO/NC,programmable
Rated operating current Ie 200 mA , short-circuit/overload protected
Default setting Switching point A1:70mm Switching point A2: 800mm
Voltage drop ≤ 2.5 V
Repeat accuracy ≤1 %
Switching frequency f ≤ 13 Hz
Range hysteresis H 2 % of the set operating distance
Temperature influence ±1.5% of full-scale value
Ambient conditions
Ambient temperature -25…70℃(248...343K)
Storage temperature -40…85℃(233...358K)
Mechanical specifications
Connection V1 connector(M12×1),4-pin
Protection degree IP67
Material Housing brass, nickel-plated
Transducer

epoxy resin/hollow glass sphere mixture;

foam polyurethane, cover PBT

2. Dimensions
RS485 Output Ultrasonic Liquid Level Sensor with 50mm~1000mm Detection Range and IP67 Protection
3. Electronic interface and signals definition
RS485 Output Ultrasonic Liquid Level Sensor with 50mm~1000mm Detection Range and IP67 ProtectionRS485 Output Ultrasonic Liquid Level Sensor with 50mm~1000mm Detection Range and IP67 Protection
4. Description of Sensor Functions
Adjust the paramater
The ultrasonic sensor features a switch output with two teachable switching points. These are set by applying the supply voltage - UB or + UB to the TEACH-IN input. The supply voltage must be applied to the TEACH-IN input for at least 1 s.LEDs indicate whether the sensor has recognised the target during the TEACH-IN procedure. Switching point A1 is taught with - UB,A2 with +UB. Eight different output functions can be set.
Switching point, Setting distance only after power on. The internal clock can assure can't be changed after 5 mins when power on. If want to change the switching point, the user can only setting the request distance after power restart.

TEACH-IN window mode, normally-open function

- Set target to near switching point

- TEACH-IN switching point A1 with - UB

- Set target to far switching point

- TEACH-IN switching point A2 with + UB

TEACH-IN window mode, normally-closed function

- Set target to far switching point

- TEACH-IN switching point A2 with - UB

- Set target to near switching point

- TEACH-IN switching point A1 with + UB

TEACH-IN switching point, normally-open function

- Set target to near switching point

- TEACH-IN switching point A1 with - UB

- Cover sensor with hand or remove all objects

from sensing range

-TEACH-IN switching point A2 with + UB

TEACH-IN switching point, normally-closed function

- Cover sensor with hand or remove all

objects from sensing range

- TEACH-IN switching point A2 with - UB

- Set target to near switching point

- TEACH-IN switching point A1 with + UB

TEAC-IN large hysteresis interval, normally-open mode

- Set target to near switching point

- TEACH-IN switching point A1 with + UB

- Set target to far switching point

- TEACH-IN switching point A2 with - UB

TEAC-IN large hysteresis interval, normally-closed mode

- Set target to far switching point

- TEACH-IN switching point A2 with + UB

- Set target to near switching point

- TEACH-IN switching point A1 with - UB

TEACH-IN detection of objects presence normally open mode

- Cover sensor with hand or remove all objects from

sensing range

- TEACH-IN switching point A2 with - UB

- Cover sensor with hand or remove all objects from

sensing range

- TEACH-IN switching point A2 with + UB

TEACH-IN detection of objects presence normally closed mode

- Cover sensor with hand or remove all objects from sensing range

- TEACH-IN switching point A2 with +UB

- Cover sensor with hand or remove all objects from sensing range

- TEACH-IN switching point A2 with -UB

Default setting of switching point

A1=blind range,A2=nominal distance

RS485 Output Ultrasonic Liquid Level Sensor with 50mm~1000mm Detection Range and IP67 Protection
LED displays
Displays in dependence on operating mode Red LED Yellow LED

TEACH-IN switching point

Object detected

No object detected

Object uncertain(TEACH-IN invalid)

off flashes On

flashes off

off

Normal operation off Switching state
Fault on Previous state
5. Installation conditions

If the sensor is installed at the environment temperature fall below 0℃,It should do well on the protective measures. In case of direct mounting of the sensor in a through hole using the steel nuts, it has to be fixed at the middle of the housing thread.

6. Shipment & payment
RS485 Output Ultrasonic Liquid Level Sensor with 50mm~1000mm Detection Range and IP67 Protection

Product Tags:

RS485 Output Liquid Level Sensor

      

Food Factory Fluid Level Meter

      

1000mm Liquid Level Sensor

      
Quality RS485 Output Ultrasonic Liquid Level Sensor with 50mm~1000mm Detection Range and IP67 Protection for sale

RS485 Output Ultrasonic Liquid Level Sensor with 50mm~1000mm Detection Range and IP67 Protection Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Xi'an Kacise Optronics Co.,Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)