| Sign In | Join Free | My benadorassociates.com | 
 | 
Brand Name : KACISE
Model Number : KGD-MQ-522
Certification : CE
Place of Origin : CHINA
MOQ : 1PCS
Payment Terms : L/C,D/A,D/P,T/T,Western Union,MoneyGram
Supply Ability : 1000 Piece/Pieces per Week negotiable
Delivery Time : 5-8 work days
Packaging Details : each unit has individual box and all boxes are packed in standard packages or customers requests available
Measurement Components : H2, N2, O2, CO, CO2, CH4, C2H2, C2H4, C2H6, C3H6, C3H8, H2S
Measurement Range : 0 - 100% (Range can be selected according to on - site conditions)
Measurement Precision : ≤ ±1%F.S.
Repeatability : ≤1%
Response Time : ≤10s
Operating Temperature : 10℃ - 35℃
KGD - MQ - 522 Laser Raman Spectroscopy Gas Analyzer
Product Introduction
The KGD - MQ - 522 Laser Raman Spectroscopy Gas Analyzer optimizes the optical path and structure, greatly reducing the overall size of the Raman analyzer. The new - generation product is more compact and portable. Based on the principle of laser Raman scattering, the KGD - MQ - 522 enhances, collects, processes, and identifies the characteristic Raman scattering spectra of the gas to be measured. It can perform quantitative calculations on gas components, enabling online and real - time qualitative and quantitative monitoring of various gases. With a second - level response, there is no need for long waiting.

Product Features
Laser Raman Spectroscopy Technology
Laser Raman spectroscopy technology is a spectral gas analysis technology based on gas Raman scattering. It uses a laser with high beam quality to emit laser light of a specific wavelength, which is focused in the gas chamber through an achromatic lens. At the focal point, the laser collides with gas molecules to generate Raman scattering. The intensity of the Raman characteristic peak is proportional to the gas concentration value. By measuring and analyzing the position and intensity of the Raman characteristic peak with a spectrometer, simultaneous measurement of multi - component gases can be achieved. Since the excitation and collection of the Raman scattering spectrum occur instantaneously and in a very short time, and signal collection can be carried out in real - time, compared with chromatography and mass spectrometry, the Raman spectrometer has a faster response speed.
Technical Parameters
| Measurement Components | H2, N2, O2, CO, CO2, CH4, C2H2, C2H4, C2H6, C3H6, C3H8, H2S | 
| Measurement Range | 0 - 100% (Range can be selected according to on - site conditions) | 
| Measurement Precision | ≤ ±1%F.S. | 
| Repeatability | ≤1% | 
| Response Time | ≤10s | 
| Operating Temperature | 10℃ - 35℃ | 
| Power Supply | AC220V/50Hz, <70W | 
| External Interfaces | USB, RS - 232, RS - 485, Ethernet | 
| Viewing Port | 605*483*220(mm) | 
|   | 
| Fast and Accurate C3H8 Measurement with KGD MQ 522 Laser Raman Spectroscopy Gas Analyzer Images | 
 Highly T90≤30s Response Time Refrigerant Gas Sensor KGD-AM-204 with RS485 Modbus
                                                                                    
                        
                        
                        
                                                            Highly T90≤30s Response Time Refrigerant Gas Sensor KGD-AM-204 with RS485 Modbus
                                                    
                        
                     KFK - G60 - TSP Factory Dust Surveillance Pro
                                                                                    
                        
                        
                        
                                                            KFK - G60 - TSP Factory Dust Surveillance Pro
                                                    
                        
                     M20*1.5 Mounting Thread Nitrogen Oxide Sensor KGD 325 For Diesel Vehicle
                                                                                    
                        
                        
                        
                                                            M20*1.5 Mounting Thread Nitrogen Oxide Sensor KGD 325 For Diesel Vehicle
                                                    
                        
                     R1234ZE Refrigerant Leakage Monitoring Sensor KGD-AM-205 Non-dispersive Infrared
                                                                                    
                        
                        
                        
                                                            R1234ZE Refrigerant Leakage Monitoring Sensor KGD-AM-205 Non-dispersive Infrared
                                                    
                        
                     KFK - G60 Flammable Gas Sentinel
                                                                                    
                        
                        
                        
                                                            KFK - G60 Flammable Gas Sentinel
                                                    
                        
                     Wide - Range Oxygen Sensor KGD - 324
                                                                                    
                        
                        
                        
                                                            Wide - Range Oxygen Sensor KGD - 324
                                                    
                        
                     Refrigerant (R744) Leakage Monitoring Sensor KGD - AM - 206
                                                                                    
                        
                        
                        
                                                            Refrigerant (R744) Leakage Monitoring Sensor KGD - AM - 206
                                                    
                        
                     Laser Scattering Sampling Method Industrial Dust Guardian KFK-G60-TSP with DC24V
                                                                                    
                        
                        
                        
                                                            Laser Scattering Sampling Method Industrial Dust Guardian KFK-G60-TSP with DC24V
                                                    
                        
                     Limiting Current - Type Oxygen Sensor KGD - 323
                                                                                    
                        
                        
                        
                                                            Limiting Current - Type Oxygen Sensor KGD - 323
                                                    
                        
                     KGD OPC 201 28.3L Particle Counter with Multi channel Counting Efficiency of 50%
                                                                                    
                        
                        
                        
                                                            KGD OPC 201 28.3L Particle Counter with Multi channel Counting Efficiency of 50%